Ludlum Model 14c

All Time Past 24 Hours Past Week Past month

Listing Results Ludlum Model 14c

Ludlum Model 14C Manual drct.com

6 hours ago Drct.com Show details

Subject: Image Created Date: 20041115143608-0600

Preview ("PDF/Adobe Acrobat")Show more

Category: Ludlum model 14c survey meter

LUDLUM MODEL 14C SURVEY METER

2 hours ago Eko-teknik.com Show details

Model 14C Survey Meter Ludlum Measurements, Inc. Page 1 March 2016 1. Introduction he Model 14C is a rugged, portable survey instrument that operates on two standard "D" cell alkaline batteries. The instrument features a regulated high voltage power supply set at

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

LUDLUM MODEL 14C SURVEY METER WITH PANCACKE GM …

7 hours ago Jgravengaard.com Show details

nuclear medicine applications, the portable Model 14C Survey Meter with Pancake GM Probe meets the essential monitoring and surveying needs of most Nuclear Medicine facilities. The external pancake probe is used to check hands, clothing, floors, furniture, equipment, and packages for contamination and background readings. For beta-emitters, the

File Size: 433KB
Page Count: 1

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

Model 14C Ludlum Measurements

9 hours ago Ludlums.com Show details

Features. This general purpose, handheld analog ratemeter supports operating two separate radiation detectors. A switch allows the user to select between the internally mounted GM detector with an exposure range of 0 - 20 mSv/h (0 - 2000 mR/hr) or an external GM or scintillator detector of choice (see table below).

Application: Alpha, Beta, and Gamma surveying

("HTML/Text")Show more

Category:: User Guide Manual

Ludlum Model 14c drct.com

4 hours ago Drct.com Show details

The Ludlum Model 14C survey meter was designed to meet nuclear medicine requirements. The Model 14C is similar to the Model 3, but with an internal energy compensated G-M detector. It can be used with one or more external GM or scintillation detectors for alpha, beta, or gamma detection up to 0-200 mR/hr.

("HTML/Text")Show more

Category:: User Guide Manual

Model 14CRK Emergency Response Kit Ludlum …

2 hours ago Ludlums.com Show details

Features. The 14C-RK Emergency Kit packages all the basic radiation measurement tools needed to handle a radiological emergency into a convenient carrying case to facilitate a quick response when required. The kit includes the robust and versatile Model 14C Survey Meter, which houses an internal energy compensated GM tube to perform exposure

("HTML/Text")Show more

Category:: Ge User Manual

Ludlum Measurements Nuclear Instrumentation

4 hours ago Drct.com Show details

Ludlum Measurements Radition Detectors General Purpose Survey Meters. Model 3 GM-Scintillation Survey Meter (Model 3 pdf version) Model 3A Alarming Survey Meter Model 14C Survey Meter for Nuclear Medicine Applications Model 12 Ratemeter Model 16 Analyzer Model 18 Analyzer . Specialized Portable Meters

("HTML/Text")Show more

Category:: User Guide Manual

Ludlum Model 3 Manual drct.com

4 hours ago Drct.com Show details

Subject: Image Created Date: 20060117160914-0600

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

Ludlum Model 12 Manual drct.com

9 hours ago Drct.com Show details

The Ludlum Model 12 Count Ratemeter This manual includes general description, provides the required electronic circuitry for control functions, operation, calibration, radiation monitoring with proportional, maintenance instructions and theory of scintillation and G-M detectors. operation. 2. SPECIFICATIONS

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

Ludlum Model 3 Operation Manual Air Quality

9 hours ago Fieldenvironmental.com Show details

Model 3 Technical Manual Section 2 Ludlum Measurements, Inc. Page 2-1 February 2013 Getting Started Unpacking and Repacking Remove the calibration certificate and place it in a secure location. Remove the instrument and accessories (batteries, cable, etc.) and ensure that all of the items listed on the packing list are in the carton.

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

Model 14C Overview YouTube

3 hours ago Youtube.com Show details

An overview of the Ludlum Model 14C Survey Meter. The Model 14C supports operating two separate radiation detectors, an internal GM detector and an external

("HTML/Text")Show more

Category:: User Guide Manual

Ludlum Model 14C Survey Meter – CHP Consultants – Products

8 hours ago Chpconsultants.com Show details

This general purpose, handheld analog ratemeter supports operating two separate radiation detectors. A switch allows the user to select between the internally mounted GM detector with an exposure range of 0–2000 mR/hr (0–20 mSv/h) or an external GM or scintillator detector of choice. Add a Counts.Pro for $399 to digitize your surveys and

("HTML/Text")Show more

Category:: Hp User Manual

LUDLUM MODEL 3 SURVEY METER TTT Environmental

Just Now Tttenviro.com Show details

Model 3 Technical Manual Section 1 Ludlum Measurements, Inc. Page 1-1 February 2010 Introduction he Model 3 is a portable radiation survey instrument with four linear ranges used with exposure rate or cpm (counts per minute) meter dials, or a combination of bothexposure rate and count rate (referred to as “combo”) meter face dials.

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

Radiation Detectors & Geigers Ludlum Meter

Just Now Troutunderground.com Show details

This is a Ludlum Model 14C Survey Meter With 44-7 Alpha. Beta, Gamma Probe What you will get: Ludlum Model 14C Survey Meter(Cal Due 8/8/2006) LUDLUM MODEL 44-7 Alpha. Beta, Gamma Detector Interconnect Cable Printout of the instruction manual from the link below.

("HTML/Text")Show more

Category:: Ge User Manual, Iat User Manual, Tec User Manual

Ludlum Measurements, Inc JRT Associates

9 hours ago Jrtassociates.com Show details

when required. The kit includes Ludlum’s robust and versatile Model 14C Ratemeter that includes an internal energy compensated GM tube to perform exposure rate measurements up to 2000 mR/hr. Responders can either plug in the external alpha beta gamma GM pancake probe (Model 44-9) for contamination measurements or the (Model 44-2)

Preview ("PDF/Adobe Acrobat")Show more

Category:: Iat User Manual

Medical Center (TAMC).

7 hours ago Nrc.gov Show details

our most sensitive radiation survey instrument, a Ludlum Model 12 with a probe model 44-3 (Low Energy Gamma Scintillator) consisting of a 7 mg/cm2 (Aluminum) and 8 mg/cm2 (Mylar) window. Supplemental spot-check monitoring was performed by utilizing a Ludlum Model 14C with a pancake G-M probe, model 44-9, with a 1.5-2 mg/cm2 (mica) window. d.

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

Ludlum Model 4438 BetaGamma Detector Manual.

7 hours ago Nrc.gov Show details

LUDLUM MODEL 44-38 BETA-GAMMA DETECTOR June 2011 Serial Number PR107884 and Succeeding Serial Numbers LUDLUM MEASUREMENTS, INC. 501 OAK STREET, P.o BOX 810 SWEETWATER, TEXAS 79556 325-235-5494, FAX 325-2354672

Preview ("PDF/Adobe Acrobat")Show more

Category:: Tec User Manual

Radiation Protection Instrument Manual

4 hours ago Pnnl.gov Show details

Instrument Manual (PNL-MA-562) which was previously maintained by PNNL as a controlled manual. The Hanford Instrument Evaluation Committee (HIEC) provides guidance on the content of PNL-MA-562 to ensure that it is a viable resource for …

Preview ("PDF/Adobe Acrobat")Show more

Category:: Iat User Manual, Tec User Manual

Model 26 Integrated Frisker Ludlum Measurements

8 hours ago Ludlums.com Show details

The cable-less Model 26 consolidates the electronics and the detector into one ergonomic housing. This optimized configuration incorporates a standard 15.51 cm 2 GM pancake probe, loud audio “click” output, and large auto-ranging LCD display with automatic back lighting into one convenient package, making it easier than ever to detect

("HTML/Text")Show more

Category:: Integra User Manual

U.S. NUCLEAR REGULATORY COMMISSION REGION I

7 hours ago Nrc.gov Show details

Ludlum Model 14C survey meter. The labels stated that the material was generally licensed per 10 CFR 31.5. The Kay-Ray/Sensall Model 7062B gauges were Serial Numbers S96F1209, S96F1213 and S96C0115. The Coates representatives remove the gauges from the mezzanine and placed them in a locked storage cabinet in locked unused office. C. Conclusions

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

McComas Enterprises Inc. Van H. McComas, MS, DABR,

7 hours ago Nrc.gov Show details

Following this survey we used the Ludlum 14C with the 44-3 NaI probe and again found no readings of the cabinet, floor, or counter greater than background at 0.08 mR/hr. Swipes of the counter was taken and measured using the Ludlum 14C with the 44-3 NaI probe. The readings were no greater than background at 200 cpm. /w7'773

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

LUDLUM MODEL 22412 SURVEY METER TTT Enviro

5 hours ago Tttenviro.com Show details

Model 2241-2 . Technical Manual . Section 1. Ludlum Measurements, Inc. Page 1-2 March 2010 . All of the features described above may be programmed manually using the internal switch board or by computer through the RS-232 port. Two different detector operating parameters may be stored in non-volatile memory.

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

LUDLUM MODEL 449 TTT Enviro

3 hours ago Tttenviro.com Show details

The Ludlum Model 449 will operate with any Ludlum - instruments or equivalent instruments that provide 900 Vdc Refer to drawing 2 × 206 located on page 7 of this manual to assist with replacement. 1. Remove the back plate by removing the three screws. 2. Loosen the three set screws on the side of the tube housing.

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

Model 177 Benchtop Counter Ludlum Measurements

9 hours ago Ludlums.com Show details

The Model 177 is a rugged benchtop ratemeter with an alarm. This instrument is very popular for frisking operations at stations where line power is available. It can also be used in portable applications for up to 50 hours using the internal rechargeable battery. The Model 177 supports GM and scintillation type detectors and displays the

("HTML/Text")Show more

Category:: User Guide Manual

INSTRUMENTATION RENTAL AND CALIBRATION SERIVCES

5 hours ago Perma-fix.com Show details

Ludlum Model 239-1F Floor Monitor w/Model 2350-1 or 2360 Data Logger $210 $525 Ludlum Model 14C Survey Meter w/ 44-38 Energy Compensated G-M Detector $50 $125 Ludlum Model 12-4 w/42-31H Neutron Counter $120 $300 Ludlum Model 15 w/42-9 Neutron Counter and 44-7 Gamma Detector $110 $275 Canberra iSolo Gas-less Manual Alpha / Beta Counting

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

Ludlum Model 14C Calibration EnergySolutions Instrument

3 hours ago Instruments.energysolutions.com Show details

Ludlum Model 14C Calibration. $124.00. (No reviews yet) Write a Review. Write a Review. ×. Ludlum Model 14C Calibration. Rating Required Select Rating 1 star (worst) 2 stars 3 stars (average) 4 stars 5 stars (best) Name. Email Required.

("HTML/Text")Show more

Category:: User Guide Manual

Instrument Manuals

6 hours ago Nukeworker.com Show details

Also, Ludlum does have manuals available for download as stated, but only for their most current products. For older equipment email them the model number & serial & they'll send you the manual applicable to that unit. Sometimes you have email them more than once to get them to respond.

("HTML/Text")Show more

Category:: User Guide Manual

Radiation Detectors & Geigers Ludlum 3 2

8 hours ago Troutunderground.com Show details

Ludlum Model 14C general purpose survey meter and Ludlum 44-9 Probe. 35" BNC Cable. Included. exactly as specified in the Ludlum site PDF for this probe. and the internal pancake probe likewise. A Ludlum Model 3 owners manual copy is included. Its current calibration tracks nicely with my own calibrated unit. Shipping to the USA is $17.90.

("HTML/Text")Show more

Category:: Ge User Manual, Iat User Manual, Tec User Manual

Ludlum Probe Survey Meter 4438 14C radiadetecbus.com

4 hours ago Radiadetecbus.com Show details

ludlum 14c Is Similar To: Ludlum Model 3 Survey Meter Geiger Counter 0818279010008 (54.4% similar) If you have any questions please look at the faq section at the bottom of the listing. We only ship to the 48 contiguous states with no exceptions. What kind of warranty do you offer we are a pawn shop and every item we list came out of our store.

("HTML/Text")Show more

Category:: Tec User Manual

Ludlum Model 14C Rental EnergySolutions

Just Now Instruments.energysolutions.com Show details

Ludlum Model 14C Monthly Rental. $93.00 (No reviews yet) Write a Review Write a Review ×. Ludlum Model 14C Monthly Rental. Rating

("HTML/Text")Show more

Category:: User Guide Manual

Model 261 Integrated GM Pancake Frisker

6 hours ago Lacoonline.com Show details

The Ludlum Model 26-1 incorporates elec-tronics and a time-tested GM (Geiger-Mueller) detector in an ergonomically designed, rug-gedly-constructed, and water-resistant housing. The integrated unit is cable-less thereby simpli-fying the process of frisking people and ob-jects. The optimized configuration includes a

Preview ("PDF/Adobe Acrobat")Show more

Category:: Integra User Manual

Radiation Detectors & Geigers Ludlum Model

Just Now Troutunderground.com Show details

This is a Ludlum Model 14C Survey Meter With 44-7 Alpha. Beta, Gamma Probe What you will get: Ludlum Model 14C Survey Meter(Cal Due 8/8/2006) LUDLUM MODEL 44-7 Alpha. Beta, Gamma Detector Interconnect Cable Printout of the instruction manual from the link below.

("HTML/Text")Show more

Category:: Ge User Manual, Iat User Manual, Tec User Manual

Ludlum Product Catalogs and Price List

4 hours ago Radsafetypro.com Show details

Radiation Safety & Protection, LLC 6555 Sugarloaf Parkway Suite 307-333 Duluth, GA 30097 Phone: (770) 363-0925 Email:  [email protected]

("HTML/Text")Show more

Category:: User Guide Manual

Model

5 hours ago Radiationsafety.ca Show details

Model . Victoreen Models 190I, 290, 410, 440 RDF, 450, 450B, 450P, 451, 451B, 451L, Panoramic 470A . Inovision : 451P, 451 . SE International Radiation Alert Monitor

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

Radiation Detectors & Geigers Ludlum Detector

3 hours ago Troutunderground.com Show details

The Ludlum Model 3 will last decades. It operates on two"D" cells for approximately 2000 hours. The Ludlum Model 3 has adjustable high voltage to 1500 volts and includes external calibration controls. The four counting ranges are x0.1, x1, x10, x100. Typical Counting Range is from 0- 200 mR/hr, or 0- 500,000 cpm.

("HTML/Text")Show more

Category:: Ge User Manual, Iat User Manual, Tec User Manual

Ludlum 481611 Survey Probe Alpha Geiger Radiation Meter

6 hours ago Radiadetecbus.com Show details

country/region of manufacture: united states, mpn: 48-1611, model: 14-c, short description: title: Ludlum 48-1611 Survey Probe Alpha Geiger Radiation Meter 14-C Beta Gamma Pancake 14C 44-9, Brand: Ludlum, Mpn: 48-1611, Model: 14-c, Country/region Of Manufacture: United States, sku: 1356787733963271, brand: ludlum, category: business & industrial > mro supply > …

("HTML/Text")Show more

Category:: Ge User Manual, Iat User Manual

Instrumentation Rental and Calibration Services

8 hours ago Perma-fix.com Show details

Ludlum Model 14C Survey Meter w/ 44-38 Energy Compensated G-M Detector . $50 . $125 . Ludlum Model 12-4 w/42-31H Neutron Counter $120 $300 Ludlum Model 15 w/42-9 Neutron Counter and 44-7 Gamma Detector . Canberra iSolo Gas-less Manual Alpha / Beta Counting System $600 $1,500

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

Ludlum Measurements, Inc Field Environmental

9 hours ago Fieldenvironmental.com Show details

Model 3-IS: Intrinsic safety rating for operating in hazardous areas (Part No. 48-3581) Model 14C: Includes internal GM detector with range of 0–20 mSv/h (0–2000 mR/hr) (Part No. 48-1611) Introduction This is Ludlum’s best selling, general purpose, handheld analog ratemeter known for accuracy and long-lasting dependability.

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

NRC: Home Page

7 hours ago Nrc.gov Show details

NRC: Home Page

Preview ("PDF/Adobe Acrobat")Show more

Category:: Ge User Manual

Intravascular Brachy seedos.co.uk

8 hours ago Seedos.co.uk Show details

NEW (April 2003) IVB 1000 Well Chamber and all and latest Inserts, pdf brochure. Please Click here for a new (Nov 2002) Click here for the User Manual for the IVB 1000 Chamber, in PDF Format. Ludlum Model 14C with thin walled GM tube ; Primealert.

("HTML/Text")Show more

Category:: User Guide Manual

GM Pancake Detectors

Just Now Ehs.berkeley.edu Show details

G-M tube. For example, Ludlum Measurements sells the 44-9, Bicron sells the PGM probe, and Thermo Electron Corporation sells the HP-260. These typically consist of a flat cylinder that houses the tube and a smaller cylindrical handle that extends off at a slight angle. 8 RSO Magazine Volume 10, No. 5 2005

Preview ("PDF/Adobe Acrobat")Show more

Category:: Tec User Manual

RadEye™ AB100 AlphaBeta Contamination Monitor

8 hours ago Thermofisher.com Show details

The RadEye AB100 Alpha-Beta Contamination Monitor provides surface contamination measurements with excellent alpha/beta discrimination to meet the radiation exposure standards and regulations in rugged industrial environments. Light Weight (900g), excellent grip with or without gloves. Compact and light weight design.

("HTML/Text")Show more

Category:: Monitor User Manual

Model 1247 Stuart Hunt

2 hours ago Stuarthunt.com Show details

Tel: 800-622-0828 / 325-235-5494 / Fax: 325-235-4672 / Email: ludlum@ludlums.com Nov 2017 Specifi cations INDICATED USE: neutron dose rate MEASUREMENT RANGE: 0–100 mSv/h (0–10,000 mrem/hr) Model 12-4-7 Neutron Dose Ratemeter. Title: M12-4 …

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

Ludlum Model 17 Ion Chamber lacoonline.com

7 hours ago Lacoonline.com Show details

Ludlum Model 17 Ion Chamber Model 17 Ion Chamber INDICATED USE: General purpose survey CHAMBER CONSTRUCTION: Carbon coated acrylic CHAMBER VOLUME: 78 cm³ WINDOW: 7 mg/cm² aluminized mylar WINDOW AREA: Active - 40 cm² Open - 30 cm² BETA SHIELD: Retractable 211 mg/cm² phenolic slide

Preview ("PDF/Adobe Acrobat")Show more

Category:: User Guide Manual

Please leave your comments here:

Maybe you need

New User Manuals

Frequently Asked Questions

What is the Ludlum Model 14C used for?

The Ludlum Model 14C is similar to their Model 3. But with an internal energy compensated Geiger–Muller (G-M) detector. It can be used with one or more external GM or scintillation detectors for alpha, beta, or gamma detection from 0-200 mR/hr.

Which Ludlum Model should I Choose?

The Ludlum Model 3 and 44-9 is the lab standard because of its rugged all metal case, general reliability, and ease of operation. The model 3 has an analog meter as well as the characteristic audible chirp.

Which Ludlum probe should I buy?

Beta, Gamma probe. The Ludlum Model 3 and 44-9 is the lab standard because of its rugged all metal case, general reliability, and ease of operation. The model 3 has an analog meter as well as the characteristic audible chirp. The speaker has an on/off switch so you can kill the noise if you wish.

What will you receive in this Ludlum auction?

What youwill receive in this auction: Ludlum Model 14C Survey Meter (Lastcalibration was 6-20-11) Ludlum Model 44-9 GM Pancake• Ludlum Model 44-38 GM Beta-Gamma Detector• Interconnect Cable*No batteries are included in this auction.

Popular Search